FORGOT YOUR DETAILS?

Column Pipe

Specification

  • Maximum : Ambient Temprature
  • Maximum Installation depth 370m
  • Instalation : Vertical, Horizontal or Inclined

Application

  • Water rising for submersible and jet pump for irrigation, domestic industrial mining, chemical distribution
  • A wise replacement for MS, ERW, GI, HDPE and stainless steel column pipes
  • uPVC is nearly insert towards corrosion, chemical reaction and erosion; due to which, it is ideally used in salty, sandy and chemically aggressive water without any effect over ther years.

TECHNICAL DETAILS

Load pulling capacity in (kg.)Pipe Size25mm32mm40mm50mm65mm80mm100mm125mm
MEDIUM8931392151014072800320048007540
STANDARD150817401972243636005010725010440
HEAVY--23003255425066121250016240

TECHNICAL PARAMETERS

Product RangeAll dimensions are in mm
Nominal DiameterO.D. NomO.D.Over Connection max.MediumStandardHeavy
mminchWall thicknessWall thicknessWall thickness
25133.6046.13.705.10-
321 ¼"42.1655.14.405.30-
401 ½"48.2662.54.805.406.00
502"60.3279.04.906.307.50
632 ¼"63.0090.05.006.607.90
652 ½"73.291.86.806.809.10
803"88.90110.06.007.6010.10
1004"114.30136.56.508.6012.20
1255"140.00165.07.7010.21-